Chemical Analysis Program for the Time of Flight Mass Spectrometry System

Authors

  • Abdullah Kepceoğlu
  • Hamdi Şükür Kılıç

DOI:

https://doi.org/10.18100/ijamec.263976

Keywords:

Mass Spectrometry, Data Acquisition, Data Processing, Statistical Analysis, GUI, MATLAB

Abstract

: In this work, we present a computer program that reads, manipulates, analyses and stores the mass spectra obtained by using Laser Time of Flight Mass Spectrometry (L-TOF-MS) system described elsewhere.  This program allows users to record the characteristic parameters of experimental data such as vacuum pressure, voltages, laser power, sample name etc. both manually and automatically.  Also, the obtained mass spectra can be used to investigate chemical substances (NO x , SO x , organic molecules etc.) or can be used to real time identification of the sample differences for given material database (metal oxides, alloys, paintings, healthy and cancerous tissues etc.) by using different mathematical and statistical procedures (PCA, LDA, kNN etc.).  We have recently presented a simple chemical analysis procedure by starting from reading raw MS data from oscilloscope using TCP/IP protocol and following data processing steps.  We have a great success to reduce the numbers of steps and time duration consumed for the following procedure.

Downloads

Download data is not yet available.

References

Angeletti, R., Gioacchini, A. M., Seraglia, R., Piro, R., & Traldi, P. (1998). The potential of matrix-assisted laser desorption/ionization mass spectrometry in the quality control of water buffalo mozzarella cheese. J Mass Spectrom, 33(6), 525-531. doi:10.1002/(SICI)1096-9888(199806)33:6<525::AID-JMS655>3.0.CO;2-S

Balog, J., Szaniszlo, T., Schaefer, K.-C., Denes, J., Lopata, A., Godorhazy, L., . . . Toth, M. (2010). Identification of biological tissues by rapid evaporative ionization mass spectrometry. Analytical Chemistry, 82(17), 7343-7350.

Balsiger, H., Altwegg, K., Bochsler, P., Eberhardt, P., Fischer, J., Graf, S., . . . Wollnik, H. (2007). Rosina - Rosetta orbiter spectrometer for ion and neutral analysis. Space Science Reviews, 128(1-4), 745-801. doi:10.1007/s11214-006-8335-3

Berman, E. S., Levin, N. E., Landais, A., Li, S., & Owano, T. (2013). Measurement of δ18O, δ17O, and 17O-excess in water by off-axis integrated cavity output spectroscopy and isotope ratio mass spectrometry. Analytical Chemistry, 85(21), 10392-10398.

Briois, C., Thissen, R., Thirkell, L., Aradj, K., Bouabdellah, A., Boukrara, A., . . . Colin, F. (2016). Orbitrap mass analyser for in situ characterisation of planetary environments: Performance evaluation of a laboratory prototype. Planetary and Space Science, 131, 33-45.

Brouwers, E. E., Tibben, M., Rosing, H., Schellens, J. H., & Beijnen, J. H. (2008). The application of inductively coupled plasma mass spectrometry in clinical pharmacological oncology research. Mass Spectrom Rev, 27(2), 67-100. doi:10.1002/mas.20159

Bruins, A. (1994). Atmospheric-pressure-ionization mass spectrometry: II. Applications in pharmacy, biochemistry and general chemistry. TrAC Trends in Analytical Chemistry, 13(2), 81-90.

Catharino, R. R., Milagre, H. M. S., Saraiva, S. A., Garcia, C. M., Schuchardt, U., Eberlin, M. N., . . . de Souza, V. (2007). Biodiesel typification and quality control by direct infusion electrospray ionization mass spectrometry fingerprinting. Energy & Fuels, 21(6), 3698-3701. doi:10.1021/ef7003078

Cheng, H., Edwards, R. L., Shen, C. C., Polyak, V. J., Asmerom, Y., Woodhead, J., . . . Alexander, E. C. (2013). Improvements in Th-230 dating, Th-230 and U-234 half-life values, and U-Th isotopic measurements by multi-collector inductively coupled plasma mass spectrometry. Earth and Planetary Science Letters, 371, 82-91. doi:10.1016/j.epsl.2013.04.006

Chu, N. C., Taylor, R. N., Chavagnac, V., Nesbitt, R. W., Boella, R. M., Milton, J. A., . . . Burton, K. (2002). Hf isotope ratio analysis using multi-collector inductively coupled plasma mass spectrometry: an evaluation of isobaric interference corrections. Journal of Analytical Atomic Spectrometry, 17(12), 1567-1574. doi:10.1039/b206707b

Downloads

Published

01-12-2016

Issue

Section

Research Articles

How to Cite

[1]
“Chemical Analysis Program for the Time of Flight Mass Spectrometry System”, J. Appl. Methods Electron. Comput., pp. 57–60, Dec. 2016, doi: 10.18100/ijamec.263976.

Similar Articles

51-60 of 199