UDE Based Robust Control of Grid Tied Inverters
Abstract
Author Affiliations
- Akın USLU — ADANA BİLİM VE TEKNOLOJİ ÜNİVERSİTESİfingerprint0000-0003-0336-2659
References (18)
- 1
M. Lindgren and J. Svensson, “Control of a voltage-source converter connected to the grid through an LCL-filter-application to active filtering,” in Proc. IEEE Power Electron. Spec. Conf., May 1998, pp. 229–235.
- 2
W. Li, X. Ruan, D. Pan, and X. Wang, “Full-feedforward schemes of grid voltages for a three-phase LCL-type grid-connected inverter,” IEEE Trans. Ind. Electron., vol. 60, no. 6, pp. 2237–2250, Jun. 2013.
- 3
Q. Zhao, Y. Ye, G. Xu, and M. Zhu, “Improved repetitive control scheme for grid-connected inverter with frequency adaptation,” IET Power Electron., vol. 9, no. 5, pp. 883–890, Apr. 2016.
- 4
R. Teodorescu, F. Blaabjerg, M. Liserre, and P. C. Loh, “Proportional resonant controllers and filters for grid-connected voltage-source converters,” in Proc. Elect. Power Appl., vol. 153, no. 5, pp. 750–762, Sep. 2006.
- 5
S. Tong, Y. Li, and S. Sui, “Adaptive fuzzy tracking control design for SISO uncertain nonstrict feedback nonlinear systems,” IEEE Trans. Fuzzy Syst., vol. 24, no. 6, pp. 1441–1454, Dec. 2016
- 6
N. Kumar, T. K. Saha, and J. Dey, “Sliding-mode control of PWM dual inverter-based grid-connected PV system: Modeling and performance analysis,” IEEE J. Emerg. Sel. Topics Power Electron., vol. 4, no. 2, pp. 435–444, Jun. 2016.
- 7
E. Sariyildiz and K. Ohnishi, “Stability and robustness of disturbanceobserver- based motion control systems,” IEEE Trans. Ind. Electron., vol. 62, no. 1, pp. 414–422, Jan. 2015.
- 8
J. Han, “From PID to active disturbance rejection control,” IEEE Trans. Ind. Electron., vol. 56, no. 3, pp. 900–906, Mar. 2009.
- 9
B. Ren, Q.-C. Zhong, and J. Dai, “Asymptotic reference tracking and disturbance rejection of UDE-based robust control,” IEEE Trans. Ind. Electron., vol. 64, no. 4, pp. 3166–3176, Apr. 2017.
- 10
J. Ren, Y. Ye, G. Xu, Q. Zhao, and M. Zhu, “Uncertainty-and-disturbanceestimator- based current control scheme for PMSM drives with a simple parameter tuning algorithm,” IEEE Trans. Power Electron., vol. 32, no. 7, pp. 5712–5722, Jul. 2017.
- 11
Q.-C. Zhong, A. Kuperman, and R. K. Stobart, “Design of UDE-based controllers from their two-degree-of-freedom nature,” Int. J. Robust Nonlinear Control, vol. 21, no. 17, pp. 1994–2008, Nov. 2011.
- 12
J. Chen, B. Ren, and Q.-C. Zhong, “UDE-based trajectory tracking control of piezoelectric stages,” IEEE Trans. Ind. Electron., vol. 63, no. 10, pp. 6450–6459, Oct. 2016.
- 13
B. Ren, Y.Wang, and Q.-C. Zhong, “UDE-based control of variable-speed wind turbine systems,” Int. J. Control, vol. 90, no. 1, pp. 137–152, 2017.
- 14
J. Ren, Y. Ye, G. Xu, Q. Zhao, and M. Zhu, “Uncertainty and disturbance estimator-based current control scheme for PMSM drives with a simple parameter tuning algorithm,” IEEE Trans. Power Electron., vol. 32, no. 7, pp. 5712–5722, Jul. 2017,
- 15
I. Aharon, D. Shmilovitz, and A. Kuperman, “Robust output voltage control of multimode non-inverting DC-DC converter,” Int. J. Control, vol. 90, no. 1, pp. 110–120, 2017.
- 16
S. Y. Gadelovits, Q.-C. Zhong, V. Kadirkamanathan, and A. Kuperman, “UDE-based controller equipped with a multi-band-stop filter to improve the voltage quality of inverters,” IEEE Trans. Ind. Electron., vol. 64, no. 9, pp. 7433–7443, Sep. 2017.
- 17
Y. Ye and Y. Xiong, “UDE-based current control strategy for LCCL-type grid-tied inverters,” IEEE Trans. Ind. Electron., vol. 65, no. 5, pp. 4061– 4069, May 2018.
- 18
R. Errouissi, M. Ouhrouche, W.-H. Chen, and A. M. Trzynadlowski, “Robust nonlinear predictive controller for permanent-magnet synchronous motors with an optimized cost function,” IEEE Trans. Ind. Electron., vol. 59, no. 7, pp. 2849–2858, Jul. 2012